Home WTI User's Guides
cover
1. Introduction
2. Unit Description
2.1. Front Panel
2.2. Back Panel PSU-82C
2.3. Back Panel PSU-82SP
3. Installation
3.1. Configure SetUp Switches
3.1.1. PSU-82C SetUp Switches
3.1.1.1. PSU-82C Baud Rate Bank 1 DIP 1
3.1.1.2. PSU-82C Parity Bank 1 DIPs2-3
3.1.1.3. PSU-82C Handshake Bank 1 DIP 4
3.1.1.4. PSU-82C Default Printer Bank 1 DIP 5
3.1.1.5. PSU-82C Automatic TOF Bank 1 DIP 6
3.1.1.6. PSU-82C Timeout Value Bank 1 DIPs7-8
3.1.1.7. PSU-82C IBM Auto-Feed Bank 2 DIP 1
3.1.1.8. Printer Output Mode Bank 2 DIPs3-4
3.1.2. PSU-82SP SetUp Switches
3.1.2.1. PSU-82SP Input Baud Rate Sw1
3.1.2.2. PSU-82SP Output Baud Rate Sw2
3.1.2.3. PSU-82SP Parity Sw3
3.1.2.4. PSU-82SP Handshake Format Sw4
3.1.2.5. PSU-82SP Default Printer Sw5
3.1.2.6. PSU-82SP Automatic TOF Sw6
3.1.2.7. PSU-82SP Timeout Value Sw7 Sw8
3.1.2. PSU-82SP SetUp Switches
3.1.2.1. PSU-82SP Input Baud Rate Sw1
3.1.2.2. PSU-82SP Output Baud Rate Sw2
3.1.2.3. PSU-82SP Parity Sw3
3.1.2.4. PSU-82SP Handshake Format Sw4
3.1.2.5. PSU-82SP Default Printer Sw5
3.1.2.6. PSU-82SP Automatic TOF Sw6
3.1.2.7. PSU-82SP Timeout Value Sw7 Sw8
3.1.2.8. PSU-82SP Printer Output Mode Sw9 Sw10
3.2. Initialize Unit
3.3. Connect Power Cable
3.4. Initial Check
3.5. Connect Printers
3.6. Connect Computers
3.7. Final Check
4. Operation
4.1. Additional Front Panel Functions
4.1.1. Send Test Message
4.1.2. RAM Test - Initialize Unit
4.2. Operation Summary
A. Interface Descriptions
A.1. Serial Ports
A.1..1. Serial Input Cabling Suggestions
A.1..2. Serial Output Cabling Suggestions
A.2. 36-Pin Parallel Interface -PSU-82SP
A.3. 25-Pin Parallel Interface
B. Troubleshooting
C. Application Example
D. Linking Several PSUs
E. Options and Accessories
F. Specifications
G. Customer Service
H. FCC Statement
Trademark and Copyright Information
82C - PSU-82SP

E. Options and Accessories

 

PSA-2 Parallel-to-Serial Adapters

WTI's PSA-2 parallel-to-serial adapter connects to a PC's 25-pin parallel port and converts it to a 25-pin male serial port. It can greatly extend the distance restrictions of parallel ports. Printers, plotters and printer sharing units can be located over 500 feet from the computer.

The PSA-2 transmits at 1200, 9600 or 19.2K baud and responds to Ready/Busy hardware flow control signals. Since it is a transmit only device, the PSA-2 does not respond to XON/XOFF characters.

Snap Adapters and Phone Cables

WTI offers a selection of RS-232 to telephone cable (RJ11) Snap™ Adapters and six conductor phone cables for use with your PSU. Please contact WTI for assistance in selecting the appropriate Snap Adapters for your application.

Memory Expansion

Memory expansion kits are available from WTI to increase PSU memory storage to 512 KBytes, 1 Megabytes, or 2 Megabytes. Complete installation instructions are supplied with each kit.

 

Apx-11

PSU-82C / PSU-82SP User’s Guide

Data Cables

WTI offers a full line of serial and parallel data cables for most applications. Here are some cables you can use with the PSUs. M= male, F= female. Substitute cable length -10, 15, 25, 50 or 100 ft. for LL below.

 

RS422 Options

The PSU can be ordered with an RS422 interface in place of any RS-232 ports. Contact WTI for ordering information.

WTI’s LD-4 RS422 Line Driver is available to connect the PSU to an RS422 interface, or to extend data transmission up to one mile. The unit is self-powered and has LED indicators to monitor the data transmission.

Apx-12