Home WTI User's Guides
cover
1. Introduction
2. Unit Description
2.1. Front Panel Indicators
2.2. Back Panel
3. Hardware Installation
3.1. Set-Up Switches
3.1.1. Default Baud Rate for Computer
3.1.2. Default Baud Rate for PBX Input Ports A and B
3.1.3. Direct Connect Mode
3.1.4. Computer Port Password
3.1.5. Power Up Default
3.2. Connecting the Data Cables and Telephone Line
3.2.1. PBX Inputs A and B
3.2.2. Modem Port
3.2.3. Computer Port
3.3. Connect the AC Power Cable
4. Program Set-Up
4.1.1. Reset Default Parameters - Clear Memory
4.1.2. Set General Parameters
4.1.2.1. Select Duplex Mode
4.1.2.2. Set Clock and Calendar
4.1.2.3. Set Communication Parameters
4.2. Define PBX Data Input Format
4.2.1. Define End-of-Record Character
4.2.2. Strip Non-Printable Codes Function
4.2.3. Time-Date Stamp Function
4.2.4. Enable-Disable Wrap Around Mode
4.3. Define Data Output Format
4.3.1. Select-Configure Data Output Mode
4.3.1.1. ASCII Record Mode
4.3.1.2. ASCII Block Mode
4.3.1.3. Binary Block Mode
4.3.1.4. XMODEM Mode
4.3.2. The CRC Function
4.3.3. The Line I.D. Function
4.3.4. Select Compression Mode
4.3.1.2. ASCII Block Mode
4.3.1.4. XMODEM Mode
4.3.2. The CRC Function
4.3.3. The Line I.D. Function
4.3.1.1. ASCII Record Mode
4.3.1.2. ASCII Block Mode
4.3.1.3. Binary Block Mode
4.3.1.4. XMODEM Mode
4.3.2. The CRC Function
4.3.3. The Line I.D. Function
4.3.4. Select Compression Mode
4.3.5. Release Data with Command B02
4.3.6. Hold END DATA Message
4.4. Callback Features
4.4.1. Define Callback Parameters
4.4.2. Scheduled Callback
4.4.3. 80 Full Callback
4.4.4. Immediate Callback
4.4.5. No-Data Alarm
4.4.6. Toll Fraud Alarm
4.5. Define Header Message-Auto Execute Command-Report Mode Command String
4.5.1. Header Message
4.5.2. The Auto Execute Command
4.5.3. The Report Mode Command String
4.6. The Data Filter
4.7. The Alarm Filter
5. The No-Data Alarm
5.1. Timer Schedules
5.2. Enabling the No-Data Alarm
6. The Data Filter
6.1. Defining the Data Filter Format
6.2. Defining Data Filter Parameters
6.3. Enabling the Data Filter
6.4. Logical and Relational Operators
6.4.1. Equal To Conditions
6.5. Logical AND OR Conditions
6.5.1. AND Conditions
6.5.2. OR Conditions
6.6. Data Filter Parameter Definition Examples
7. The Alarm Filter
7.1. The Alarm Filter Format
7.1.1. Common Types of Suspect Phone Activity
7.1.2. Defining the Alarm Filter Format
7.2. Alarm Clues
7.2.1. Alarm Clue Definition
7.2.2. Enabling the Alarm Filter
7.2.3. Logical and Relational Operators
7.2.3.1. Logical AND-OR Conditions
7.2.4. Real-Time Variables
7.2.5. Testing Alarm Clues
7.3. Selecting an Alarm Notification Method
7.3.1. Alarm Off
7.3.2. Local Alarm
7.3.3. Remote Alarm
7.3.4. Pager
7.3.5. Report
7.3.6. Pager
7.3.7. Switching Alarm Methods
7.3.8. The Alarm Message
7.4. Responding to a Toll Fraud Alarm
7.4.3. Reset ALM LED and Alarm Port
7.4.4. Displaying Alarm Data
7.4.5. Clear Alarm Condition
7.4.6. Resetting Alarm Clue Counters
7.4.7. The Pass-Through Mode and the Monitor Mode
8. Saving PollCat III Parameters
8.1. B99 Command Options
8.2. Saving Parameters to an ASCII File
8.3. Configuring PollCat III with Saved Parameters
9. Polling Accumulated Data
9.1. The Data Release Mode
9.1.1. Data Release Command Options
9.2. Polling
9.2.1. Example 1 Polling Device Calls PollCat III Via Modem
9.2.4. Example 4 XMODEM Polling
10. Command Reference Guide
10.1. Access to Command Mode
10.2. Command Syntax
10.3. Command Summary
A. Advanced Format and Clue Definition
A.1. Alarm Filter Format Definition
A.2. Alarm Clue Definition
A.2.1. Alarm Clue Examples
A.2.1.1. Repeated Attempts to Access Voice Mail
A.2.1.4. Unusual International Calls
A.2.1.5. Calls to Your Competitors
A.2.1.6. Calls to 900 Numbers
A.2.1.7. Calls From a Particular Extension
A.2.1.8. The Contains String Operator
A.3. Clue Definition Logic
A.3.1. Headers Banners and Other Non-Data
A.3.2. The Comparative Operators
A.3.2.1. Limit the Scope of Comparisons
A.3.2.2. Exclude Non-Data Characteristics
A.3.3. Exact Match with PBX Call Record Format
A.4. Programming Support
B. Cable Installation
C.3. Alarm Port
D. PollCat II Compatibility
D.1. Alarm Filter
D.2. Port Modifications
D.3. Status Screens
D.4. Connection
D.5. Other Modified or Eliminated Commands
E. LED Indicators
F. Specifications
G. Customer Service
H. FCC Statement
I.1. Response Message Summary
Index
4.4.3. Console Port
8.6. Assigning the Data Filter to a Port
14. Scheduled Actions
PollCat III B

2.2. Back Panel

 

Figure 2.2: Back Panel

 

 

C AC Power Connector: Receptacle for AC Power Cord (included).

e Modem Port: Includes two RJ11 jacks as described below.

LINE: For connection to a telecommunications line.

PHONE: Not Used. ® Power Switch: Applies AC Power to the unit. @ AC Switch: Selects 115 VAC or 230 VAC power source. @ Fuse: Houses 250V, .25 AMP slow blow fuse.

•                      Alarm Port: For connection to an optional, external alarm unit. For a description of the Alarm Port interface, please refer to Appendix C.3.

•                      Set-Up Switches: A bank of eight dip switches used to configure communication settings, Local Access Mode, Computer Port Password, and Power Up Defaults.

•                      Computer Port: For direct cable connection between PollCat III and a local PC. The local PC can be used for polling or management of the PollCat III unit.

•                      PBX InputsA&B: For connection to the PBX SMDR Port(s).