Home WTI User's Guides
cover
1. Introduction
2. Unit Description
2.1. Front Panel Indicators
2.2. Back Panel
3. Hardware Installation
3.1. Set-Up Switches
3.1.1. Default Baud Rate for Computer
3.1.2. Default Baud Rate for PBX Input Ports A and B
3.1.3. Direct Connect Mode
3.1.4. Computer Port Password
3.1.5. Power Up Default
3.2. Connecting the Data Cables and Telephone Line
3.2.1. PBX Inputs A and B
3.2.2. Modem Port
3.2.3. Computer Port
3.3. Connect the AC Power Cable
4. Program Set-Up
4.1.1. Reset Default Parameters - Clear Memory
4.1.2. Set General Parameters
4.1.2.1. Select Duplex Mode
4.1.2.2. Set Clock and Calendar
4.1.2.3. Set Communication Parameters
4.2. Define PBX Data Input Format
4.2.1. Define End-of-Record Character
4.2.2. Strip Non-Printable Codes Function
4.2.3. Time-Date Stamp Function
4.2.4. Enable-Disable Wrap Around Mode
4.3. Define Data Output Format
4.3.1. Select-Configure Data Output Mode
4.3.1.1. ASCII Record Mode
4.3.1.2. ASCII Block Mode
4.3.1.3. Binary Block Mode
4.3.1.4. XMODEM Mode
4.3.2. The CRC Function
4.3.3. The Line I.D. Function
4.3.4. Select Compression Mode
4.3.1.2. ASCII Block Mode
4.3.1.4. XMODEM Mode
4.3.2. The CRC Function
4.3.3. The Line I.D. Function
4.3.1.1. ASCII Record Mode
4.3.1.2. ASCII Block Mode
4.3.1.3. Binary Block Mode
4.3.1.4. XMODEM Mode
4.3.2. The CRC Function
4.3.3. The Line I.D. Function
4.3.4. Select Compression Mode
4.3.5. Release Data with Command B02
4.3.6. Hold END DATA Message
4.4. Callback Features
4.4.1. Define Callback Parameters
4.4.2. Scheduled Callback
4.4.3. 80 Full Callback
4.4.4. Immediate Callback
4.4.5. No-Data Alarm
4.4.6. Toll Fraud Alarm
4.5. Define Header Message-Auto Execute Command-Report Mode Command String
4.5.1. Header Message
4.5.2. The Auto Execute Command
4.5.3. The Report Mode Command String
4.6. The Data Filter
4.7. The Alarm Filter
5. The No-Data Alarm
5.1. Timer Schedules
5.2. Enabling the No-Data Alarm
6. The Data Filter
6.1. Defining the Data Filter Format
6.2. Defining Data Filter Parameters
6.3. Enabling the Data Filter
6.4. Logical and Relational Operators
6.4.1. Equal To Conditions
6.5. Logical AND OR Conditions
6.5.1. AND Conditions
6.5.2. OR Conditions
6.6. Data Filter Parameter Definition Examples
7. The Alarm Filter
7.1. The Alarm Filter Format
7.1.1. Common Types of Suspect Phone Activity
7.1.2. Defining the Alarm Filter Format
7.2. Alarm Clues
7.2.1. Alarm Clue Definition
7.2.2. Enabling the Alarm Filter
7.2.3. Logical and Relational Operators
7.2.3.1. Logical AND-OR Conditions
7.2.4. Real-Time Variables
7.2.5. Testing Alarm Clues
7.3. Selecting an Alarm Notification Method
7.3.1. Alarm Off
7.3.2. Local Alarm
7.3.3. Remote Alarm
7.3.4. Pager
7.3.5. Report
7.3.6. Pager
7.3.7. Switching Alarm Methods
7.3.8. The Alarm Message
7.4. Responding to a Toll Fraud Alarm
7.4.3. Reset ALM LED and Alarm Port
7.4.4. Displaying Alarm Data
7.4.5. Clear Alarm Condition
7.4.6. Resetting Alarm Clue Counters
7.4.7. The Pass-Through Mode and the Monitor Mode
8. Saving PollCat III Parameters
8.1. B99 Command Options
8.2. Saving Parameters to an ASCII File
8.3. Configuring PollCat III with Saved Parameters
9. Polling Accumulated Data
9.1. The Data Release Mode
9.1.1. Data Release Command Options
9.2. Polling
9.2.1. Example 1 Polling Device Calls PollCat III Via Modem
9.2.4. Example 4 XMODEM Polling
10. Command Reference Guide
10.1. Access to Command Mode
10.2. Command Syntax
10.3. Command Summary
A. Advanced Format and Clue Definition
A.1. Alarm Filter Format Definition
A.2. Alarm Clue Definition
A.2.1. Alarm Clue Examples
A.2.1.1. Repeated Attempts to Access Voice Mail
A.2.1.4. Unusual International Calls
A.2.1.5. Calls to Your Competitors
A.2.1.6. Calls to 900 Numbers
A.2.1.7. Calls From a Particular Extension
A.2.1.8. The Contains String Operator
A.3. Clue Definition Logic
A.3.1. Headers Banners and Other Non-Data
A.3.2. The Comparative Operators
A.3.2.1. Limit the Scope of Comparisons
A.3.2.2. Exclude Non-Data Characteristics
A.3.3. Exact Match with PBX Call Record Format
A.4. Programming Support
B. Cable Installation
C.3. Alarm Port
D. PollCat II Compatibility
D.1. Alarm Filter
D.2. Port Modifications
D.3. Status Screens
D.4. Connection
D.5. Other Modified or Eliminated Commands
E. LED Indicators
F. Specifications
G. Customer Service
H. FCC Statement
I.1. Response Message Summary
Index
4.4.3. Console Port
8.6. Assigning the Data Filter to a Port
14. Scheduled Actions
PollCat III B

7.3.5. Report

 

When the Report Mode is selected, PollCat III will call your remote PC via modem when a Toll Fraud Alarm is generated. If a Report Command String has been defined (Command ^B04), the command string will be automatically executed, without the need to enter a password. If the Report Command String has not been defined, the unit will display the "PollCat III" message and wait for a password. The ALM LED and Alarm Port are enabled.

To use this mode, your system must include the following:

•                      An outside phone line connected directly to PollCat III's Modem Port.

•                      A remote PC connected to a modem.

•                      A communications program (e.g. ProComm, Crosstalk, etc.) installed and running on the remote PC.

 

When a Toll Fraud or No-Data Alarm is generated, PollCat III will notify you by dialing the number entered at ^B14's "ALARM#?" prompt. The unit will then invoke the Report Command String (Command ^B14). The unit will not send an Alarm Message, unless Command ^B13 (Send Alarm Message) is included in the Report Command String.

Note:

•                      When selected (^B87,4), the Report mode will function regardless of whether the "Auto Execute" option (^B69) is enabled or not.

•                      When the Report mode is selected, alarm callouts will not cause the Auto Execute command string to be executed.

•                      A Report callout does not automatically clear the alarm condition. The Report Mode Command string should always include the ^B84 (Clear Alarm Condition) command. This will prevent the PollCat III from calling several times for one alarm.

 

To select the Report mode, proceed as follows:

1                     Check the Set-Up Switches to make certain Switch 6 is set in the DOWN position to disable Direct Connect mode.

2                     Enter the Command Mode and type ^B87,4 [Enter] to select the Report mode.

3                     If you have not already done so, use Command ^B14 to enter the phone number for the remote modem (ALARM#). If the Report Command String will include command ^B13 (Send Alarm Message), define the Alarm Message under command ^B14's "MSG" prompt.

4                     To define a Report Command String, proceed as described in Section 4.5.3.