1. Introduction
2. Unit Description
2.1. Front Panel Indicators
2.2. Back Panel
3. Hardware Installation
3.1. Set-Up Switches
3.1.1. Default Baud Rate for Computer
3.1.2. Default Baud Rate for PBX Input Ports A and B
3.1.3. Direct Connect Mode
3.1.4. Computer Port Password
3.1.5. Power Up Default
3.2. Connecting the Data Cables and Telephone Line
3.2.1. PBX Inputs A and B
3.2.2. Modem Port
3.2.3. Computer Port
3.3. Connect the AC Power Cable
4. Program Set-Up
4.1.1. Reset Default Parameters - Clear Memory
4.1.2. Set General Parameters
4.1.2.1. Select Duplex Mode
4.1.2.2. Set Clock and Calendar
4.1.2.3. Set Communication Parameters
4.2. Define PBX Data Input Format
4.2.1. Define End-of-Record Character
4.2.2. Strip Non-Printable Codes Function
4.2.3. Time-Date Stamp Function
4.2.4. Enable-Disable Wrap Around Mode
4.3. Define Data Output Format
4.3.1. Select-Configure Data Output Mode
4.3.1.1. ASCII Record Mode
4.3.1.2. ASCII Block Mode
4.3.1.3. Binary Block Mode
4.3.1.4. XMODEM Mode
4.3.2. The CRC Function
4.3.3. The Line I.D. Function
4.3.4. Select Compression Mode
4.3.1.2. ASCII Block Mode
4.3.1.4. XMODEM Mode
4.3.2. The CRC Function
4.3.3. The Line I.D. Function
4.3.1.1. ASCII Record Mode
4.3.1.2. ASCII Block Mode
4.3.1.3. Binary Block Mode
4.3.1.4. XMODEM Mode
4.3.2. The CRC Function
4.3.3. The Line I.D. Function
4.3.4. Select Compression Mode
4.3.5. Release Data with Command B02
4.3.6. Hold END DATA Message
4.4. Callback Features
4.4.1. Define Callback Parameters
4.4.2. Scheduled Callback
4.4.3. 80 Full Callback
4.4.4. Immediate Callback
4.4.5. No-Data Alarm
4.4.6. Toll Fraud Alarm
4.5. Define Header Message-Auto Execute Command-Report Mode Command String
4.5.1. Header Message
4.5.2. The Auto Execute Command
4.5.3. The Report Mode Command String
4.6. The Data Filter
4.7. The Alarm Filter
5. The No-Data Alarm
5.1. Timer Schedules
5.2. Enabling the No-Data Alarm
6. The Data Filter
6.1. Defining the Data Filter Format
6.2. Defining Data Filter Parameters
6.3. Enabling the Data Filter
6.4. Logical and Relational Operators
6.4.1. Equal To Conditions
6.5. Logical AND OR Conditions
6.5.1. AND Conditions
6.5.2. OR Conditions
6.6. Data Filter Parameter Definition Examples
7. The Alarm Filter
7.1. The Alarm Filter Format
7.1.1. Common Types of Suspect Phone Activity
7.1.2. Defining the Alarm Filter Format
7.2. Alarm Clues
7.2.1. Alarm Clue Definition
7.2.2. Enabling the Alarm Filter
7.2.3. Logical and Relational Operators
7.2.3.1. Logical AND-OR Conditions
7.2.4. Real-Time Variables
7.2.5. Testing Alarm Clues
7.3. Selecting an Alarm Notification Method
7.3.1. Alarm Off
7.3.2. Local Alarm
7.3.3. Remote Alarm
7.3.4. Pager
7.3.5. Report
7.3.6. Pager
7.3.7. Switching Alarm Methods
7.3.8. The Alarm Message
7.4. Responding to a Toll Fraud Alarm
7.4.3. Reset ALM LED and Alarm Port
7.4.4. Displaying Alarm Data
7.4.5. Clear Alarm Condition
7.4.6. Resetting Alarm Clue Counters
7.4.7. The Pass-Through Mode and the Monitor Mode
8. Saving PollCat III Parameters
8.1. B99 Command Options
8.2. Saving Parameters to an ASCII File
8.3. Configuring PollCat III with Saved Parameters
9. Polling Accumulated Data
9.1. The Data Release Mode
9.1.1. Data Release Command Options
9.2. Polling
9.2.1. Example 1 Polling Device Calls PollCat III Via Modem
9.2.4. Example 4 XMODEM Polling
10. Command Reference Guide
10.1. Access to Command Mode
10.2. Command Syntax
10.3. Command Summary
A. Advanced Format and Clue Definition
A.1. Alarm Filter Format Definition
A.2. Alarm Clue Definition
A.2.1. Alarm Clue Examples
A.2.1.1. Repeated Attempts to Access Voice Mail
A.2.1.4. Unusual International Calls
A.2.1.5. Calls to Your Competitors
A.2.1.6. Calls to 900 Numbers
A.2.1.7. Calls From a Particular Extension
A.2.1.8. The Contains String Operator
A.3. Clue Definition Logic
A.3.1. Headers Banners and Other Non-Data
A.3.2. The Comparative Operators
A.3.2.1. Limit the Scope of Comparisons
A.3.2.2. Exclude Non-Data Characteristics
A.3.3. Exact Match with PBX Call Record Format
A.4. Programming Support
B. Cable Installation
C.3. Alarm Port
D. PollCat II Compatibility
D.1. Alarm Filter
D.2. Port Modifications
D.3. Status Screens
D.4. Connection
D.5. Other Modified or Eliminated Commands
E. LED Indicators
F. Specifications
G. Customer Service
H. FCC Statement
I.1. Response Message Summary
Index
4.4.3. Console Port
8.6. Assigning the Data Filter to a Port
14. Scheduled Actions
PollCat III B

8.3. Configuring PollCat III with Saved Parameters

 

Once PollCat III's defined parameters have been saved, the ASCII text file with the saved parameters can be uploaded to the PollCat III to re-configure the unit without manually defining each parameter.

1                     Enter PollCat III's Command Mode.

2                     Configure your communications program to define <Line Feed> as the "Pace Character". This will cause the Terminal Emulation Program to wait for a line feed before sending each line of data. Save the Setup Options for the Terminal Emulation Program.

 

a) As each line of the ASCII text file is sent, PollCat III will respond with "COMPLETE<CR><LF>". Your computer will wait for the <LF> at the end of this response before sending the next line.

b) If you are using ProComm, press [Alt]-[S] to open the Setup Utility.

i. Highlight "Protocol Options" and then press [Enter], the Protocol Options menu will appear.

ii. Highlight "ASCII Protocol Options" and press [Enter], the ASCII Protocol Options menu will appear.

iii. Type F and then type 10 and press [Enter].

iv. Press [Esc] twice, and then select "Save Setup Options".

4. Use the communications program to send the ASCII text file with the saved PollCat III parameters.

a) Set-up the communications program to send an ASCII text file and enter a file name for the file with the saved PollCat III parameters.

b) If you are using ProComm, press [Page Up] to activate the Send Parameters mode, a dialogue box will appear. Select "A -ASCII", ProComm will prompt you to enter a filename. Type in the name of the file and press [Enter].

5. As each line of the ASCII text file is sent, PollCat III will respond with the "COMPLETE" message.

PollCat III will now be configured with the saved parameters.

Note:

•                      If the file with the saved parameters is sent to PollCat III via the Computer Port (from a local PC), changes will take effect immediately.

•                      If the saved parameter file is being sent to PollCat III via the Modem Port (from a remote PC), Modem Port Communication Parameters will not take effect until after you exit from Command Mode. If Command ^B16 is invoked to display the Status Screen, the screen will not show the correct status for the Modem Port until you have exited and then re-entered Command Mode.

•                      Some parameters, such as ^B90 (Modem Port Communication Parameters) may require five to seven seconds to generate a response.