5.1. Command Mode Access
5.2. Menu System Conventions
5.3. Set System Parameters
5.3.1. The User Directory
5.3.1.1. Administrator Access
5.3.1.2. Adding New User Accounts
5.3.1.3. Editing and Deleting User Accounts
5.3.1.4. Viewing the User Directory
5.3.2 Real-Time Clock Settings
5.4. Port Configuration
5.4.1. PBX Serial Input Port
5.4.1.1. Field Suppression; The Lucent Switch Feature
5.4.2. PBX IP Port Configuration
5.4.3. Console Port Configuration
5.4.4. Modem Port Configuration
5.4.4.1. Dialback Security
5.4.5. Network Port Configuration
5.4.5.1. The IP Security Feature
5.4.5.2. The Email Text Messaging Parameters Menu
5.4.5.3. PPP Dialout Configuration
5.4.6. Push File Configuration
5.4.7. Server Configuration
6. Menu System Description
6.1. Software Tree
7. Status Screens
7.1. Buffer Status Screen
7.2. File List Screen
7.4. The User Directory
7.5 PBX Port Status Screen
7.6. The PBX IP Port Status Screen
7.7. The Console Port Status Screen
7.8. The Modem Port Status Screen
7.9. The Network Port Status Screen
7.10. Scheduled Action Status Screens
7.11. PBX Inactivity Alarm Status Screens
7.12. 80 Full Alarm Status Screen
7.13. Data Filters Alarms Status Screen
7.15. Reason for Action Screen
7.16. Alarm Filter Clue Status Screens
8. The Data Filters
8.1. The Data Filter Configuration Menus
8.2. Defining the Data Filter Format
8.3. Defining Data Filter Clues
8.4. Logical and Relational Operators 8.4. Logical and Relational Operators
8.4.1. Logical AND-OR Conditions
8.4.1.1. Logical AND Conditions
8.4.1.2. Logical OR Conditions
8.4.2. The Contains String Operator
8.5. Real Time Variables
8.6. Assigning the Data Filter to a Port
8.7. Data Filter Definition Examples
9. The Alarm Filters
9.1. Common Types of Suspect Phone Activity
9.2. The Alarm Configuration Menu
9.2.1. Default Alarm Filter Actions
9.3. The Alarm Filter Configuration Menus
9.4. Defining the Alarm Filter Format
9.5. Defining Alarm Filter Clues
9.5.1. Alarm Clue Definition
9.5.2. Editing and Deleting Clues
9.6. Logical and Relational Operators
9.6.1. Logical AND-OR Conditions
9.6.1.1. Logical AND Conditions
9.6.1.2. Logical OR Conditions
9.6.2. The Contains String Operator
9.7. Real Time Variables
9.8. Assigning the Alarm Filter to a Port
9.9. Match Parameter Definition Examples
10. PBX Inactivity Alarms
10.1. Schedules and Timers
10.2. Enabling the PBX Inactivity Alarm
11. The 80 Full Alarm
12. Alarm Actions
12.1. Alarm Actions for Alarm Filter Clues
12.2. Alarm Action Summary
12.2.1. None
12.2.2. Callout
12.2.3. Alphanumeric Page
12.2.4. Numeric Page
12.2.6. Email Text Message
12.2.7. Console
12.3. The Auto Execute Function
13. Scheduled Actions
14. Saving NetLink II Parameters
14.1. Saving Parameters to Flash Memory
14.2. Saving and Restoring Parameters from an ASCII File
14.2.1. Saving Parameters to an ASCII File
14.2.2. Saving Parameters to an ASCII File
14.3. Configuring NetLink II with Saved Parameters
15. Buffer Functions
15.1. Memory Partitions and Shared Data
15.1.1. Partitions and Files
15.1.2. Setting the Partition
15.1.3. Releasing the Partition
15.2. Menu Driven Data Release
15.2.1. The Buffer Functions Menu
15.2.2. Read Session Parameters
15.3. Command Driven Data Release
15.3.1. Command B00
15.3.2. The B01 Command Line
15.3.3. Command B01 Examples
15.3.4. Other Commands Used During Data Release
15.4. Retrieving Data Using the Push Function
15.4.1. File Names Created by the Push Function
15.4.2. Push Start Time
15.5. Retrieving Data Using the Server Function
15.5.1. File Names Created by the Server Feature
15.6. The Auto Delete Function
15.7. Zmodem Data Release Mode
16. Other Menu Functions
16.1. System Functions
16.1.1. Pass-Through Mode
16.1.2. Monitor Mode
16.1.3. Clear Alarm Condition
16.1.4. Clear Alarm Counters
16.1.5. Download Parameters
16.1.6. Audit Trail
16.1.7. Upload Firmware
16.1.8. Download SSH Server Keys
16.2. System Diagnostics
16.2.1. Load and Test Memory
16.2.2. Send Test Message
16.2.3. Test Pager
16.2.4. Send Test SNMP
16.2.5 Send Test SYSLOG Message
16.3. Reboot System
17. Command Reference Guide
17.1. Command Mode Access
17.2. Command Help
17.3. Command Syntax
17.4. Command Summary
A. Specifications
B. Description of System Interfaces
B.1. Serial PBX Input Port
B.2. Console Port
C. Administrator Functions and User Functions
C.1. Security Mode at Start Up
C.2. Dialback Security
C.3. Administrator Mode and User Mode Functions
D. Alarm Clue Definition Tips
D.1. Headers Banners and Other Non-Data
D.1.1. The Comparative Operators
D.1.1.1. Limit Comparisons
D.1.1.2. Exclude Non-Data Characteristics
D.1.2. Exact Match with PBX Call Record Format
D.2. Programming Support
E. SSH Application Notes
E.1. Windows XP - Assign a User Name
E.2. Create the User Name in the WINSSHD Application
E.3. Generate Netlink client keys
E.4. Import the Client Keys Into the WINSSHD Application
E. Customer Service
Index
PollCat NetLink II B

17.1. Command Mode Access

 

When the NetLink II has been properly installed and configured, command mode can be accessed by a local PC connected directly to the Console Port, by a remote PC that communicates via modem, or via TCP/IP network.

Notes:

•                      If the Site I.D. Message (System Parameters Menu, Item 4) has been defined, the Site I.D. will be displayed before the "PollCat-NetLink" prompt.

•                      When the Administrator Password is entered, NetLink II will start up in Administrator Mode, allowing access to all menu functions. When a User password is entered, NetLink II will start up in User Mode, which allows limited access to menu functions.

•                      The Default Administrator Mode Password is SUPER, and the default User Mode Password is SMDR.

 

1. Remote Access (via Modem): Start your communications program and dial the NetLink.

a) The unit will respond with the "PollCat-NetLink" (password) prompt after the carrier is detected.

b) Key in a valid password and press [Enter]. Note that the Password feature is case-sensitive.

c) The Main Menu or the "Ready" prompt will be displayed. If the "Ready" prompt is displayed, press [Enter] to display the NetLink II Main Menu. Note that if the Dialback Number has been defined for your User Account, NetLink II will perform a dialback operation before allowing access to command mode. For more information, please refer to Section 5.4.4.1.

2. Local Access (Console Port): Start your communications program.

a) If Set-Up Switch 1 is UP (Enable Console Port Password), the "PollCat- NetLink" (password) prompt will be displayed.

b) Key in a valid password and press [Enter]. Note that the Password feature is case-sensitive.

c) The Main Menu or the "Ready" prompt will be displayed. If the "Ready" prompt is displayed, press [Enter] to display the NetLink II Main Menu.

3. Access via TCP/IP Network: If network parameters for the NetLink II unit have been assigned (see Section 5.4.5), key the NetLink II's IP address into your Telnet client, or establish a telnet session using the following format:

telnet ipaddress [port] [Enter]

Where: ipaddress NetLink II's assigned IP Address.

port (Optional) The desired Port Number.  If this item is omitted, telnet will connect to port #23 by default; Command Echo will be set according to NetLink II's current configuration, and $FF Stuffing will be enabled. Options:

2001 Behaves the same as Port #23. 3001 Preconfigured with echo enabled and $FF Stuffing Off.

a) If the password is enabled, the "PollCat-NetLink" (password) prompt will appear.

b) Key in a valid password and press [Enter]. Note that the Password feature is case-sensitive.

c) After a brief pause, the Main Menu or the "Ready" prompt will appear.  If the "Ready" prompt is displayed, press [Enter] to display the NetLink II Main Menu.

d) To end a session, disconnect using your Telnet software.

Notes:

•                      In order to control or configure the unit via network, you must first access command mode via the Modem Port or Console Port, and enable the Telnet Access option (Network Parameters Menu, Item 31) as described in Section 5.4.5.

•                      When the NetLink II unit is reset to default parameters, Telnet Access will be disabled by default.

 

17-2