Home WTI User's Guides
cover
Warnings and Cautions
1. Introduction
2. Unit Description
2.1. Front Panel Indicators
2.2. Back Panel
3. Quick Start Guide
3.2. Hardware Installation
3.2.1. Apply Power to the NetLink II
3.2.2. Connect your PC to the NetLink II
3.3. Communicating with the NetLink II
3.3.1. Access via Console Port or Modem
3.3.2. Access via Network
3.4. Connect your PBX to the NetLink II
4. Hardware Installation
4.1. Connect the NetLink II to your Power Supply
4.2. Set-Up Switches
4.2.1. Console Port Password
4.2.2. Power Up Console Defaults
4.2.3 Modem Speaker
4.3. Reset to Defaults
4.4. Connecting Cables and Phone Line
4.4.1. PBX Input Port
4.4.2. Modem Port
4.4.3. Console Port
4.4.4. Network Port
5. Configuration
5.1. Command Mode Access
5.2. Menu System Conventions
5.3. Set System Parameters
5.3.1. The User Directory
5.3.1.1. Administrator Access
5.3.1.2. Adding New User Accounts
5.3.1.3. Editing and Deleting User Accounts
5.3.1.4. Viewing the User Directory
5.3.2 Real-Time Clock Settings
5.4. Port Configuration
5.4.1. PBX Serial Input Port
5.4.1.1. Field Suppression; The Lucent Switch Feature
5.4.2. PBX IP Port Configuration
5.4.3. Console Port Configuration
5.4.4. Modem Port Configuration
5.4.4.1. Dialback Security
5.4.5. Network Port Configuration
5.4.5.1. The IP Security Feature
5.4.5.2. The Email Text Messaging Parameters Menu
5.4.5.3. PPP Dialout Configuration
5.4.6. Push File Configuration
5.4.7. Server Configuration
6. Menu System Description
6.1. Software Tree
7. Status Screens
7.1. Buffer Status Screen
7.2. File List Screen
7.4. The User Directory
7.5 PBX Port Status Screen
7.6. The PBX IP Port Status Screen
7.7. The Console Port Status Screen
7.8. The Modem Port Status Screen
7.9. The Network Port Status Screen
7.10. Scheduled Action Status Screens
7.11. PBX Inactivity Alarm Status Screens
7.12. 80 Full Alarm Status Screen
7.13. Data Filters Alarms Status Screen
7.15. Reason for Action Screen
7.16. Alarm Filter Clue Status Screens
8. The Data Filters
8.1. The Data Filter Configuration Menus
8.2. Defining the Data Filter Format
8.3. Defining Data Filter Clues
8.4. Logical and Relational Operators 8.4. Logical and Relational Operators
8.4.1. Logical AND-OR Conditions
8.4.1.1. Logical AND Conditions
8.4.1.2. Logical OR Conditions
8.4.2. The Contains String Operator
8.5. Real Time Variables
8.6. Assigning the Data Filter to a Port
8.7. Data Filter Definition Examples
9. The Alarm Filters
9.1. Common Types of Suspect Phone Activity
9.2. The Alarm Configuration Menu
9.2.1. Default Alarm Filter Actions
9.3. The Alarm Filter Configuration Menus
9.4. Defining the Alarm Filter Format
9.5. Defining Alarm Filter Clues
9.5.1. Alarm Clue Definition
9.5.2. Editing and Deleting Clues
9.6. Logical and Relational Operators
9.6.1. Logical AND-OR Conditions
9.6.1.1. Logical AND Conditions
9.6.1.2. Logical OR Conditions
9.6.2. The Contains String Operator
9.7. Real Time Variables
9.8. Assigning the Alarm Filter to a Port
9.9. Match Parameter Definition Examples
10. PBX Inactivity Alarms
10.1. Schedules and Timers
10.2. Enabling the PBX Inactivity Alarm
11. The 80 Full Alarm
12. Alarm Actions
12.1. Alarm Actions for Alarm Filter Clues
12.2. Alarm Action Summary
12.2.1. None
12.2.2. Callout
12.2.3. Alphanumeric Page
12.2.4. Numeric Page
12.2.6. Email Text Message
12.2.7. Console
12.3. The Auto Execute Function
13. Scheduled Actions
14. Saving NetLink II Parameters
14.1. Saving Parameters to Flash Memory
14.2. Saving and Restoring Parameters from an ASCII File
14.2.1. Saving Parameters to an ASCII File
14.2.2. Saving Parameters to an ASCII File
14.3. Configuring NetLink II with Saved Parameters
15. Buffer Functions
15.1. Memory Partitions and Shared Data
15.1.1. Partitions and Files
15.1.2. Setting the Partition
15.1.3. Releasing the Partition
15.2. Menu Driven Data Release
15.2.1. The Buffer Functions Menu
15.2.2. Read Session Parameters
15.3. Command Driven Data Release
15.3.1. Command B00
15.3.2. The B01 Command Line
15.3.3. Command B01 Examples
15.3.4. Other Commands Used During Data Release
15.4. Retrieving Data Using the Push Function
15.4.1. File Names Created by the Push Function
15.4.2. Push Start Time
15.5. Retrieving Data Using the Server Function
15.5.1. File Names Created by the Server Feature
15.6. The Auto Delete Function
15.7. Zmodem Data Release Mode
16. Other Menu Functions
16.1. System Functions
16.1.1. Pass-Through Mode
16.1.2. Monitor Mode
16.1.3. Clear Alarm Condition
16.1.4. Clear Alarm Counters
16.1.5. Download Parameters
16.1.6. Audit Trail
16.1.7. Upload Firmware
16.1.8. Download SSH Server Keys
16.2. System Diagnostics
16.2.1. Load and Test Memory
16.2.2. Send Test Message
16.2.3. Test Pager
16.2.4. Send Test SNMP
16.2.5 Send Test SYSLOG Message
16.3. Reboot System
17. Command Reference Guide
17.1. Command Mode Access
17.2. Command Help
17.3. Command Syntax
17.4. Command Summary
A. Specifications
B. Description of System Interfaces
B.1. Serial PBX Input Port
B.2. Console Port
C. Administrator Functions and User Functions
C.1. Security Mode at Start Up
C.2. Dialback Security
C.3. Administrator Mode and User Mode Functions
D. Alarm Clue Definition Tips
D.1. Headers Banners and Other Non-Data
D.1.1. The Comparative Operators
D.1.1.1. Limit Comparisons
D.1.1.2. Exclude Non-Data Characteristics
D.1.2. Exact Match with PBX Call Record Format
D.2. Programming Support
E. SSH Application Notes
E.1. Windows XP - Assign a User Name
E.2. Create the User Name in the WINSSHD Application
E.3. Generate Netlink client keys
E.4. Import the Client Keys Into the WINSSHD Application
E. Customer Service
Index
PollCat NetLink II B

8.3. Defining Data Filter Clues

 

Data Filter match parameters describe the specific criteria that NetLink II will use to determine if call records should be stored or discarded. Storage/ rejection criteria are referred to as "Clues". Parameters can be combined under a single clue, or divided between a series of clues to create a logical "OR" condition.

Clues are defined using item 4 in the Data Filter Configuration menu (Figure 8.1). Each clue will usually include the following:

•                      Variable(s): One or more variables from the Data Filter Format, which designate the field(s) to be monitored.  For example, the variable may represent the call record field for the number dialed.

•                      Operator(s): One or more of the logical or comparative operators described in Section 8.4.

•                      Parameter(s): A description of call characteristics which will be used as the criteria for storage or rejection. For example, specific numbers or area codes for which records will not be stored.

 

To define Data Filter clues, proceed as follows:

1                     Access the Data Filter Configuration Menu.

2                     Data Filter Action: Type 1 and press [Enter] to specify whether the filter will store or reject records that match Clue Parameters.

3                     Define Clues: Type 4and press [Enter] to define parameters that will be used as the criteria for storage or rejection. The Define/Edit Clue menu will appear.

 

a) Clue Name: Type 1and press [Enter] to assign a Clue Name. This name can be used to reference a specific clue when altering or deleting clues.

b) Match Parameters: Type 2and press [Enter] to define the criteria for storage or rejection. Match Parameters consist of one or more variable(s) from the Data Filter Format, one of the logical operators discussed in Section 8.4, and the value that will be matched (e.g., the number dialed).

Example: If the Data Filter Format assigns "A" to represent the call record field for the number dialed, then A=5551212tells NetLink II to check this field for the number "5551212".

c) Match Parameters may reference several variables, may include logical operators, and may also include logical AND/OR conditions. Please refer to the examples in Section 8.7.

 

1                     Display Clue Details: Item 3 can be used to review clue parameters. Type 3and press [Enter], NetLink II will list all defined clue names.  Key in the name of the desired clue and press [Enter]; parameters for the specified clue will be displayed.

2                     Edit Clues: To alter an existing Clue, type 5and press [Enter]. NetLink II will list all clue names defined for the current filter.  Key in the desired clue name and then press [Enter]. The Define/Edit Clue menu will be displayed, allowing the user to edit clue parameters.

3                     Delete Clues: To delete an existing Clue, type 6and press [Enter]. NetLink II will list all clue names defined for the current filter.  Key in the name of the clue you that wish to delete and press [Enter]; the clue will be deleted.

 

Note: Deleted clues cannot be automatically restored.