Home WTI User's Guides
cover
Warnings and Cautions
1. Introduction
2. Unit Description
2.1. Front Panel Indicators
2.2. Back Panel
3. Quick Start Guide
3.2. Hardware Installation
3.2.1. Apply Power to the NetLink II
3.2.2. Connect your PC to the NetLink II
3.3. Communicating with the NetLink II
3.3.1. Access via Console Port or Modem
3.3.2. Access via Network
3.4. Connect your PBX to the NetLink II
4. Hardware Installation
4.1. Connect the NetLink II to your Power Supply
4.2. Set-Up Switches
4.2.1. Console Port Password
4.2.2. Power Up Console Defaults
4.2.3 Modem Speaker
4.3. Reset to Defaults
4.4. Connecting Cables and Phone Line
4.4.1. PBX Input Port
4.4.2. Modem Port
4.4.3. Console Port
4.4.4. Network Port
5. Configuration
5.1. Command Mode Access
5.2. Menu System Conventions
5.3. Set System Parameters
5.3.1. The User Directory
5.3.1.1. Administrator Access
5.3.1.2. Adding New User Accounts
5.3.1.3. Editing and Deleting User Accounts
5.3.1.4. Viewing the User Directory
5.3.2 Real-Time Clock Settings
5.4. Port Configuration
5.4.1. PBX Serial Input Port
5.4.1.1. Field Suppression; The Lucent Switch Feature
5.4.2. PBX IP Port Configuration
5.4.3. Console Port Configuration
5.4.4. Modem Port Configuration
5.4.4.1. Dialback Security
5.4.5. Network Port Configuration
5.4.5.1. The IP Security Feature
5.4.5.2. The Email Text Messaging Parameters Menu
5.4.5.3. PPP Dialout Configuration
5.4.6. Push File Configuration
5.4.7. Server Configuration
6. Menu System Description
6.1. Software Tree
7. Status Screens
7.1. Buffer Status Screen
7.2. File List Screen
7.4. The User Directory
7.5 PBX Port Status Screen
7.6. The PBX IP Port Status Screen
7.7. The Console Port Status Screen
7.8. The Modem Port Status Screen
7.9. The Network Port Status Screen
7.10. Scheduled Action Status Screens
7.11. PBX Inactivity Alarm Status Screens
7.12. 80 Full Alarm Status Screen
7.13. Data Filters Alarms Status Screen
7.15. Reason for Action Screen
7.16. Alarm Filter Clue Status Screens
8. The Data Filters
8.1. The Data Filter Configuration Menus
8.2. Defining the Data Filter Format
8.3. Defining Data Filter Clues
8.4. Logical and Relational Operators 8.4. Logical and Relational Operators
8.4.1. Logical AND-OR Conditions
8.4.1.1. Logical AND Conditions
8.4.1.2. Logical OR Conditions
8.4.2. The Contains String Operator
8.5. Real Time Variables
8.6. Assigning the Data Filter to a Port
8.7. Data Filter Definition Examples
9. The Alarm Filters
9.1. Common Types of Suspect Phone Activity
9.2. The Alarm Configuration Menu
9.2.1. Default Alarm Filter Actions
9.3. The Alarm Filter Configuration Menus
9.4. Defining the Alarm Filter Format
9.5. Defining Alarm Filter Clues
9.5.1. Alarm Clue Definition
9.5.2. Editing and Deleting Clues
9.6. Logical and Relational Operators
9.6.1. Logical AND-OR Conditions
9.6.1.1. Logical AND Conditions
9.6.1.2. Logical OR Conditions
9.6.2. The Contains String Operator
9.7. Real Time Variables
9.8. Assigning the Alarm Filter to a Port
9.9. Match Parameter Definition Examples
10. PBX Inactivity Alarms
10.1. Schedules and Timers
10.2. Enabling the PBX Inactivity Alarm
11. The 80 Full Alarm
12. Alarm Actions
12.1. Alarm Actions for Alarm Filter Clues
12.2. Alarm Action Summary
12.2.1. None
12.2.2. Callout
12.2.3. Alphanumeric Page
12.2.4. Numeric Page
12.2.6. Email Text Message
12.2.7. Console
12.3. The Auto Execute Function
13. Scheduled Actions
14. Saving NetLink II Parameters
14.1. Saving Parameters to Flash Memory
14.2. Saving and Restoring Parameters from an ASCII File
14.2.1. Saving Parameters to an ASCII File
14.2.2. Saving Parameters to an ASCII File
14.3. Configuring NetLink II with Saved Parameters
15. Buffer Functions
15.1. Memory Partitions and Shared Data
15.1.1. Partitions and Files
15.1.2. Setting the Partition
15.1.3. Releasing the Partition
15.2. Menu Driven Data Release
15.2.1. The Buffer Functions Menu
15.2.2. Read Session Parameters
15.3. Command Driven Data Release
15.3.1. Command B00
15.3.2. The B01 Command Line
15.3.3. Command B01 Examples
15.3.4. Other Commands Used During Data Release
15.4. Retrieving Data Using the Push Function
15.4.1. File Names Created by the Push Function
15.4.2. Push Start Time
15.5. Retrieving Data Using the Server Function
15.5.1. File Names Created by the Server Feature
15.6. The Auto Delete Function
15.7. Zmodem Data Release Mode
16. Other Menu Functions
16.1. System Functions
16.1.1. Pass-Through Mode
16.1.2. Monitor Mode
16.1.3. Clear Alarm Condition
16.1.4. Clear Alarm Counters
16.1.5. Download Parameters
16.1.6. Audit Trail
16.1.7. Upload Firmware
16.1.8. Download SSH Server Keys
16.2. System Diagnostics
16.2.1. Load and Test Memory
16.2.2. Send Test Message
16.2.3. Test Pager
16.2.4. Send Test SNMP
16.2.5 Send Test SYSLOG Message
16.3. Reboot System
17. Command Reference Guide
17.1. Command Mode Access
17.2. Command Help
17.3. Command Syntax
17.4. Command Summary
A. Specifications
B. Description of System Interfaces
B.1. Serial PBX Input Port
B.2. Console Port
C. Administrator Functions and User Functions
C.1. Security Mode at Start Up
C.2. Dialback Security
C.3. Administrator Mode and User Mode Functions
D. Alarm Clue Definition Tips
D.1. Headers Banners and Other Non-Data
D.1.1. The Comparative Operators
D.1.1.1. Limit Comparisons
D.1.1.2. Exclude Non-Data Characteristics
D.1.2. Exact Match with PBX Call Record Format
D.2. Programming Support
E. SSH Application Notes
E.1. Windows XP - Assign a User Name
E.2. Create the User Name in the WINSSHD Application
E.3. Generate Netlink client keys
E.4. Import the Client Keys Into the WINSSHD Application
E. Customer Service
Index
PollCat NetLink II B

Warnings and Cautions

 

Warnings and Cautions: INSTALLATION INSTRUCTIONS SECURE RACKING

 

 

If Secure Racked units are installed in a closed or multi-unit rack assembly, they may require further evaluation by Certification Agencies. The following items must be considered.

1                     The ambient within the rack may be greater than room ambient. Installation should be such that the amount of air flow required for safe operation is not compromised. The maximum temperature for the equipment in this environment is 45°C. Consideration should be given to the maximum rated ambient.

2                     Installation should be such that a hazardous stability condition is not achieved due to uneven loading.

 

INPUT SUPPLY

1                     Check nameplate ratings to assure there is no overloading of supply circuits that could have an effect on overcurrent protection and supply wiring.

2                     When installing 48 VDC rated equipment, it must be installed only per the following conditions:

 

A. Connect the equipment to a 48 VDC supply source that is electrically isolated from the alternating current source. The 48 VDC source is to be connected to a 48 VDC SELV source.

B. Input wiring to terminal block must be routed and secured in such a manner that it is protected from damage and stress. Do not route wiring past sharp edges or moving parts.

C. A readily accessible disconnect device, with a 3 mm minimum contact gap, shall be incorporated in the fixed wiring.

GROUNDING

Reliable earthing of this equipment must be maintained. Particular attention should be given to supply connections when connecting to power strips, rather than direct connections to the branch circuit.

No Serviceable Parts Inside; Authorized Service Personnel Only

Do not attempt to repair or service this device yourself. Internal components must be serviced by authorized personnel only.

• Shock Hazard - Do Not Enter

Disconnect Power

If any of the following events are noted, immediately disconnect the unit from the outlet and contact qualified service personnel:

1                     If the power cord becomes frayed or damaged.

2                     If liquid has been spilled into the device or if the device has been exposed to rain or water.

 

FCC Part 15 Regulation

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation

WARNING:  Changes or modifications to this unit not expressly

approved by the party responsible for compliance could void the user’s

authority to operate the equipment

Industry Canada

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

This product meets the applicable Industry Canada technical specifications

The Ringer Equivalence Number is an indication of the maximum number of devices allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices does not exceed five